Kyungjae LEE , Inyoung YANG , Yangji LEE , Sanghoon LEE

DOI Number XXX-YYY-ZZZ

Conference Number HiSST-2022-13

A performance test rig for heat exchanger of a supersonic regenerative cooling combustor was
developed in Korea Aerospace Research Institute. The 500 hp compressor was used to supply air of
more than 2 bar and the air was heated through two electric air heaters, which had a capacity of 300
kW and 400 kW, respectively. Max. air flow is about 0.7 kg/s and max. air temperature is about 600
℃. The heated air is accelerated up to Mach 2 with supersonic nozzle. A preliminary performance test
was carried out with heat exchanger of a supersonic regenerative cooling combustor model at Mach 2
air flow and air temperature was varied from 300 to 500 ℃. And room temperature water was supplied
as a fuel and coolant of heat exchanger instead of real fuel for safety reason.

Read the full paper >

Email
Print
LinkedIn
The paper above was part of  proceedings of a CEAS event and as such the author has signed a publication agreement to have their paper published in the repository. In the case this paper is found somewhere else CEAS always links to the other source.  CEAS takes great care in making the correct content available to the reader. If any mistakes are found  in the listings please contact us directly at papers@aerospacerepository.org and we will correct the listing promptly.  CEAS cannot be held liable either for mistakes in editorial or technical aspects, nor for omissions, nor for the correctness of the content. In particular, CEAS does not guarantee completeness or correctness of information contained in external websites which can be accessed via links from CEAS’s websites. Despite accurate research on the content of such linked external websites, CEAS cannot be held liable for their content. Only the content providers of such external sites are liable for their content. Should you notice any mistake in technical or editorial aspects of the CEAS site, please do not hesitate to inform us.